Help / Graphs

Graphs

Panels, cards, zooming, dragging past the end of a log, the legend, per-channel axis ranges, race zero and comparing.

One to four panels

The small 1 2 3 4 buttons in the top-left of the upper graph choose how many panels you see. All four are offered on the Graph tab, which has the whole window; on the Gauges and Histograms tabs the pane is shared with the dashboard or the table, so three is the most.

The fourth panel is added above the bottom graph, so a channel on the lower panel stays on the bottom whether you show two, three or four. Drop back to fewer panels and channels on a hidden panel are drawn on the bottom one instead of vanishing; they return to their own panel when you go back.

Above the graphs, a card per selected channel shows its live value with minimum, maximum and average for the log. Past eight cards the rest are behind + N more selected channels.

Zooming and panning

Drag a graphPan through the log. Both panels stay locked together.
WheelZoom around the pointer.
Shift + dragDrag out a span and release to zoom to it.
↑ ↓Zoom in and out around the cursor.
← →Step the cursor one sample.
The red windowDrag it to move; drag either edge to zoom that end only; click the bar anywhere else to centre there.
+ −Zoom buttons beside the overview bar.
⛶Fullscreen. In the phone and tablet apps this button closes the log instead.
↻ Reset ZoomBack to the whole log.

On a touch screen one finger moves the cursor and two fingers pan or pinch, so you can read values without the graph sliding around.

Dragging past the end

A run that ends at the finish line leaves the interesting part jammed against the right edge. You can drag the graph past either end of the log, by up to half a screen, so the last samples sit where you can read them. The empty part is shaded, with a dashed line marked log end or log start, so a gap never looks like missing data. Zoom right out and the view snaps back to exactly the log.

The legend

Docked, HP Tuners style. Each graph's legend starts docked in a column down its left side, every channel shown as its name and unit over a large value in its own colour, with its value at the cursor. The column always fits its graph: when space runs short the text steps down, busy graphs pair the tiles or switch to a compact list, and long names are abbreviated word by word, never scrolled or cut off at the end. Only on a graph too short to show every channel at any size do the last few step out, counted by a small +N you can hover to see them. All the graphs dock together, so their time axes stay lined up under one crosshair. Click the × beside a channel to take it off the graph.

Floating. Drag any docked column out onto a graph and every legend becomes a small window over its graph instead; the one you dragged lands where you let go. Drag a floating legend to move it, drag its corner handle to resize it, and double-click it to put it back in its corner. Drag one to the left edge of its graph (the strip lights up) to dock them all again. Floating is remembered once you choose it, and saved with a Layout.

Colours. Right-click a channel in the legend, docked or floating, or its card, and pick a colour: its line, its axis numbers, its name and value in the legend and its card all change together. Custom colour opens a full colour picker, and Default colour puts it back. The colour stays with that channel on every log you open, and is saved with a Layout.

Right-click a graph

The menu opens headed with the exact time you clicked, and holds two things. To change a channel's colour, right-click its name in the legend instead (see The legend).

  • Set race zero here Pro, and Clear race zero once one is set. With a comparison loaded you get one for each log, and the two are used to align them.
  • Y-axis range. One row per channel on that panel, with a minimum, a maximum and Set. Auto returns a channel to automatic scaling. Use it when one channel's spikes flatten everything else.

Race zero

Set a zero point Pro and the time axis reads from your launch instead of from the start of the file, which is what makes two runs comparable. Right-click the moment on a graph, or use Set 0 in the race row. × clears it. The overview bar marks where the zero is.

Until a zero is set, the same readout shows Time: the log's own time at the cursor, as it was recorded. Setting a zero switches it to Race in amber; clearing it switches back.

Comparing two logs

Analyze → Compare a second log Pro draws a second log over the same axes. The compare bar names it and says whether it is aligned on race zero or aligned on start, with nudge buttons of 50 ms and 500 ms either way, the current offset, a reset, and × to remove the comparison.

Every channel in the graph legend shows both values at the cursor: your log's, and under or beside it the second log's, smaller and underlined with the same dashes as its line. It is read at the second log's own time, so nudging the alignment moves the number with the trace. Where the cursor is outside the second recording it reads -- rather than holding the last value it had.

A ≈ in front of the second value means that log calls the channel something else and it was matched by meaning — hover it to see which channel was actually read. A channel the second log does not have at all gets no second value, and no dashed line.

Cam timing (Ti-VCT)

On alldatalogs.com and in the Windows app, not in the phone apps yet. It is under Analyze while a log is open, and alldatalogs.com also gives it a page of its own at alldatalogs.com/cam-timing, for reference with no log at all.

With a log open it takes its own column on the right and the log narrows to fit beside it, so no part of a graph is hidden underneath and the log can still be scrolled and clicked while it is up. Close it and the log takes the full width again. It also opens on the right engine for the car: HP Tuners puts the VIN in a log's file name, and a Mustang's VIN gives its year, so a 2024 log opens on Gen 4; pick another generation and that choice stands. Beside a log, Camshaft B starts folded to its title bar to save height — click the bar to open it. A cam picked for B is still drawn while it is folded, and the bar names it.

Following a log. When the log also records where the cams are, camshaft A follows the cursor: its two phaser positions are read from the log as you move through it, and the two positions are shown beside the tick box. HP Tuners' Intake Cam Angle and Exhaust Cam Angle are used first, then VCT Intake / Exhaust Cam Phase Angle, SCT's variable valve timing ... actual and VCT1_INTP / VCT1_EXHP, MoTeC's VTC Intake / Exhaust Bank 1 Position, the bank 2 channels, and any other intake or exhaust cam angle or position; never a desired, target or duty-cycle channel. A channel whose values no phaser could reach (a vehicle that does not answer that PID reads 169° or 400° all log) is passed over for the next one. Untick Follow the log to hold A where the log had it and adjust from there, and use camshaft B to see how a different grind would sit at the same phaser positions. A logged position outside what the engine can physically reach is shown as it was logged and flagged, rather than quietly clamped, because that is usually a channel that is not what its name says.

Analyze → Cam timing Pro works out what a camshaft is actually doing on an engine whose cams move. Pick the Model, then its Generation (the year range), pick a cam, move the two phaser positions, and it gives you the valve events, both centrelines, overlap and the installed separation, with a valve-lift diagram drawn against crank angle; a light grey dashed line marks TDC, where overlap is centred. Pick a second cam and it is drawn over the first, dashed, with the difference in every figure. It needs no log open — it is a calculator.

Follower ratio turns a cam's lobe lift into valve lift, and it is not the same on every generation: 2.01 on 2011-17 and 1.89 on 2018 on, which is the figure GSC prints on its Gen 3 cam cards (no Gen 4 card prints one; GSC's Gen 4 grinds give the same valve lift as the same Gen 3 grinds, so Gen 3's is used). Picking an engine sets its ratio; type over it with one you have measured. It only changes cams whose maker prints lobe lift; a cam that prints valve lift is drawn at that lift.

Positions are crank degrees from park, and positive retards. That is Ford's own convention, from its published production cam timing. It is worth knowing because two other conventions are in circulation: a cam card that writes advance as a positive number, and a standalone cam controller whose table is zeroed at the end of the phaser's travel rather than at park. Numbers from either have to be converted before they are typed in here, and getting it wrong moves everything by up to fifty degrees while still looking reasonable.

Where the cams park is not the same on every generation, which is why the generation has to be chosen first. On a 2011-14 the intake parks against a stop at its retarded end and can only advance, so its number is never positive. From 2015 on the intake is centre parked, on a pin in mid travel, and moves both ways — up to 50° either side of park. The exhaust parks fully advanced on every generation and only ever retards. The panel limits each slider to what that engine can physically reach, and says so if a figure lands outside it.

For these engines Ford publishes valve lift and nothing else — no duration, no events, no centrelines, for any generation. Some entries are off a cam card, some are read out of a calibration, and some rest on figures no factory document confirms. A cam's events are only meaningful at a stated checking height, so comparing two quoted at different heights is flagged rather than quietly allowed.

The cam list is split into Factory, Aftermarket and Your own cam card. The aftermarket list holds the grinds whose makers publish enough to place them: duration at .050" and where the centrelines sit with the phasers parked. Some makers print the durations but no centreline; those are marked needs card ICL, and are drawn at a stated stand-in until you type in the intake centreline from the card that came with the cams — the exhaust follows from the lobe separation. For anything not listed, Your own cam card takes the four numbers off any card: both durations at .050" and both centrelines at park. Numbers you type are remembered on that computer.

The models. Mustang GT (2011-14, 2015-17, 2018-23 and 2024+), F-150 5.0 (2011-14, 2015-17, 2018-20 and 2021+), Boss 302, GT350, GT500, F-150 Raptor R and Mustang GTD. The F-150 stock cams are worked out from the truck's tune, which matches its Mustang's intake with the exhaust closing 1° later, and from L&M's 210°/212° for the 2021+ truck, so they are marked .050 ESTIMATE. The GT500, Raptor R and GTD share the same cams. Models marked provisional — the Boss 302, GT500, Raptor R and GTD — use figures nobody has independently confirmed for that engine, so treat them as a guide.

Where the stock cams come from. The 2018-23 Mustang GT and the GT350 come from L&M Engines' own stock-cam worksheets: the opening and closing points at .050" and at .004", so the lobes are drawn as asymmetric as they really are, from where the valve leaves its seat. The 2011-14 and 2015-17 exhausts park at 125° BTDC, L&M's figure (some cam cards say 123°). Gen 3 also has a calibration events entry, the opening and closing points stored in the tune; they are measured much lower than .050" and so read about 50° longer. Gen 4 has no published card yet: its .050 ESTIMATE is worked out from its calibration events and is the default until a stock cam is degreed.

Time slips, laps and Dragy

Analyze also takes performance data Pro: a time slip, lap times or a Dragy run. The increments draw on the graphs in race mode, so set a race zero at the launch first. Clear performance data removes it.

This page is part of the manual built into BigData for Windows, where the same topics are available offline with F1.